Skip to main content

Dew point monitor, 230V AC, two-way contact

WFRRN-210.018

Dew point monitor, 230V AC, two-way contact

Electronic dew point monitor with standard rail mounting for detecting and reporting the dew point. If the dew point sensor (TPS 1, 2, 3) is installed correctly, it prevents condensation from dripping from the cooled parts of the cooling circuit. For this purpose, a dew point sensor located at a suitable point on the cooling circuit is evaluated and a potential-free changeover contact is switched over in the event of condensation. This contact can be used for direct interruption of the cooling or for indirect interruption of the cooling by signaling to a building management system. If the optimal installation location cannot be clearly determined, it is possible to connect up to 5 dew point sensors in parallel to the controller. The activated function "Cooling interruption by dew point triggering" is indicated by a red lamp on the unit. The switching point is fixed at approx. 98% RH.
  • Art.-Nr.: D4780572

    Technical data

    Ambient temperature, lower value 0 °C
    Ambient temperature, upper value 55 °C
    Bearing temperature, lower value -20 °C
    Bearing temperature, upper value 70 °C
    Colour Light grey
    Depth 59 mm
    Electric connection Screw terminals
    Height 86 mm
    Housing material Plastic PC
    Maximum air humidity (non-condensing) 95 % r.H
    Maximum switching current 10 (3) A 230VAC, 10 A 30VDC, 1 A 60VDC
    Maximum switching voltage 230 V AC , 50 Hz / 60 V DC
    Medium Air, not aggressive
    Minimum switching current Depending on switch. voltage (min. 0.3 W)
    Minimum switching voltage Depending on switch. current (min. 0.3 W)
    Mounting / attachment On supporting rails (35 mm), EN 60715
    Number of outputs 2
    Operating voltage 230 V AC / 50 Hz
    Output signal 230 V AC, 50 Hz / 60 V DC
    Potential free switching contact Yes
    Protection class II, following appropriate mounting
    RAL colour number (similar) 7035
    Safety and EMC In accordance with DIN EN 60730
    Setting range, rel. air humidity lower value 98 %
    Setting range, rel. air humidity upper value 98 %
    Surface properties Matt
    Switching contact Two-way contact
    Switching difference, can be adjusted No
    Switching element Relay
    Type of protection IP20
    Width 36 mm
    With explosion protection No
    Circuit diagram  Circuit diagram

    Downloads

    Assembly instructions

    Datasheet

    Photo Type Articlenumber Features Kind
     

    Contact request

     

    Do you have questions or are you interested in our products?

    Please contact the electrician you trust or write us a message.

    Close Menu