Skip to main content

Frost protection thermostat, 1.8m, IP65, hysteresis 1.5K, STW, internal setting, external resetting

RTKSA-204.020

Frost protection thermostat, 1.8m, IP65, hysteresis 1.5K, STW, internal setting, external resetting

The RTKSA frost protection controllers were specially developed for air or water-side frost protection of hot water heater registers and heat exchangers in ventilation, heating or air conditioning systems. If the sensor breaks, contact 1 – 2 is permanently opened and contact 1 – 4 is permanently closed. Note: Mounting brackets, immersion sleeves and protective coils are not included in the scope of delivery and must be ordered separately. Air-side application: The SWK-2-xxx protective coils can be used to measure the temperature of non-aggressive gases in the duct. Water-side application: For temperature measurement in non-aggressive fluids, the immersion sleeves THK-2-xxx and in aggressive fluids the immersion sleeves NTHK-2-xxx can be used.
  • Art.-Nr.: KA020401

    Technical data

    Ambient temperature, upper value 80 °C
    Bearing temperature, lower value -30 °C
    Bearing temperature, upper value 80 °C
    Capillary length 1,8 m
    Colour Anthr. grey (RAL7016), frontp. transp.
    Contact interlocking No
    Control range, lower value -10 °C
    Control range, upper value 15 °C
    Cooling control function Yes
    Depth 53 mm
    Device version Surface-mounted unit
    Diameter sensor element 9,5 mm
    Electric connection Push-in terminal
    Electronic control No
    External setting No
    Function type (systems engineering) STW
    Heating control function Yes
    Height 146,8 mm
    Internal setting Yes
    Length of sensor 98 mm
    Max. sensor temperature 120 °C
    Maximum air humidity (non-condensing) 95 % r.H
    Maximum switching current O: 16 (2,5) A; S: 6,3 (2,5) A, 0,25 ADC
    Maximum switching voltage 230 V AC 50 / 60 Hz, 230 V DC
    Minimum switching current At 24 V (AC/DC) min. 100 mA
    Minimum switching voltage 24 V AC / 50 Hz, 24 V DC
    Mounting / attachment Wall mounting
    Number of control ranges 1
    Number of outputs 2
    Operating voltage None
    Operation Internal setpoint adjuster
    Output signal Switching
    Potential free switching contact Yes
    Protection class I
    Safety and EMC In accordance with DIN EN 60730
    Scale Degree Celsius
    Sensor element Capillary tube
    Sensor material Cu
    Switching contact Two-way contact
    Switching difference 1.5 K
    Switching difference, can be adjusted No
    Switching element Microswitch
    Type of protection IP65
    Width 57,6 mm
    With explosion protection No
    Circuit diagram  Circuit diagram

    Downloads

    Info sheet

    Assembly instructions